2 Mounting
2.1 Mount the sensor
Use your common practices to minimize torque and bending load on process connections.
Tip
To reduce the risk of condensation or excessive moisture, the conduit opening should not point
upward (if possible). The conduit opening of the junction box or core processor can be rotated freely
to facilitate wiring.
Procedure
Mount the sensor in the pipeline (see Figure 2-1).
Mounting the sensorFigure 2-1:
Notes
Do not use the sensor to support the piping.
The sensor does not require external supports. The flanges will support the sensor in any orientation.
CAUTION!
Do not lift the sensor by the electronics or purge connections. Lifting the sensor by the
electronics or purge connections can damage the device.
Mounting
6 Micro Motion T-Series