Instruction Manual
IM-106-910Xi, Original Issue
November 2010
A-3
Xi Advanced Electronics
Integral XPS
6A00365G01 with Xi
(for 44V Probes)
This XPS equipment configuration includes the XPS and a Xi Advanced
Electronics unit installed on a common mounting plate. This configuration is
intended to replace a World Class Intelligent Field Transmitter (IFT) where the
required input line voltage is 120/240V AC, particularly for 240 VAC
applications.
Figure A-2. Integral XPS with Xi
and 6A00365G01 Mounting
Other XPS Uses
Two XPS units can be wired to two O
2
Probes and back to one dual-channel
Xi. This avoids having to purchase a Xi for each probe and eliminates one of
two signal cables that would otherwise be required to communicate between
the Xi and XPS units.